群桩基础安全监测中噪声的分析及剥离
nalysis and dissection of noise in Safety monitoring of pile group foundation
在群桩基础安全监测中,监测数据含有大量的噪声因素。潮位影响桩基的浮力变化,温度不仅直接影响观测部位的应力分布,还会通过影响上部结构变形而引起基础的应力变化。噪声对基础的安全可靠性评价至关重要。从实际的桩基及索塔安全监测数据出发,分析潮位、温度等噪声对群桩基础应力分布的直接影响以及日照辐射及温度通过对上部结构的作用,导致下部基础应力的变化。然后用修正方法及小波理论,剔除潮位、温度等噪声影响,分析特大型桩基基础的安全性。
uring the safety monitoring for pile group foundation, monitoring data contain a lot of noise factors. Tide changes affect the buoyancy, and temperature not only directly affects the stress distribution on observation sites, but also brings the stress change of foundation by affecting the upper parts’ the structure deformation. Noise is essential for evaluating the safety and reliability of foundation. Based on the actual safety monitoring data from pile foundation and cable tower, the direct effects of temperature on the stress distribution of pile group foundation are analyzed. In addition,the upper structure is affected by sunshine and temperature, leading that the stress in the lower part of foundation is changed. Then by using the correction method and wavelet theory, noise effects such as temperature are eliminated, and the safety of large scale pile foundation is analyzed.
谢瑞丰、陈志坚、陈利、杨永健
水工结构工程基础科学地基基础工程
安全监测群桩基础温度上部结构去噪
safety monitoringpile group foundationtemperatureupper structurede-noising
谢瑞丰,陈志坚,陈利,杨永健.群桩基础安全监测中噪声的分析及剥离[EB/OL].(2010-04-23)[2025-08-02].http://www.paper.edu.cn/releasepaper/content/201004-868.点此复制