|国家预印本平台
首页|Analytical performance and concordance with next-generation sequencing of a rapid multiplexed dPCR panel for the detection of actionable DNA and RNA biomarkers in non-small cell lung cancer

Analytical performance and concordance with next-generation sequencing of a rapid multiplexed dPCR panel for the detection of actionable DNA and RNA biomarkers in non-small cell lung cancer

Analytical performance and concordance with next-generation sequencing of a rapid multiplexed dPCR panel for the detection of actionable DNA and RNA biomarkers in non-small cell lung cancer

来源:bioRxiv_logobioRxiv
英文摘要

Abstract BackgroundOver the last ten years, the discovery and FDA approval of targeted therapies for lung cancer has significantly improved patient survival rates. However, despite these improved survival rates, only 68% of patients receive molecular testing that results in assignment of targeted therapy 1,2. Barriers to timely access to biomarker information include no testing ordered3,high nucleic acid input requirements, and problematic turnaround time (TAT) by NGS (> 14 days)4.Here we report the analytical performance and concordance with next-generation sequencing (NGS) of a highly-multiplexed research use only (RUO) panel using digital PCR (dPCR). The HDPCR NSCLC panel reports the status for variants (SNV, indels, and fusions) in eight actionable genes using amplitude modulation and multi-spectral encoding in dPCR5. MethodsThe panel’s analytical sensitivity and reactivity were determined using DNA and RNA extracted from formalin-fixed paraffin-embedded (FFPE) tissue spiked with plasmid DNA or in-vitro transcribed RNA. Concordance was established on 106 FFPE samples previously characterized using the Oncomine Precision Assay? or pathology results. Discordant resolution was resolved with Archer Fusionplex? and Variantplex? panels. ResultsThe analytical sensitivity, reported as estimated mutant allele fraction (MAF), for DNA targets (EGFR exon 19 deletions, EGFR exon 20 insertions, EGFR S768I, EGFR L858R, EGFR T790M, EGFR L861Q, BRAF V600E, EGFR G719X, ERBB2 exon 20 insertions and KRAS G12C) ranged from 0.8% – 4.9% with 40 ng of DNA input, and 2.4% to 10.9% with 15 ng of DNA input. For RNA fusion targets (ALK, RET, ROS, NTRK 1/2/3, and MET exon 14 skipping), the analytical sensitivity ranged from 24 - 150 copies with 5 ng of total RNA input. The population prevalence-based coverage ranged from 89.2% to 100.0% across targets and >99.0% in aggregate. The accuracy of the assay was >97% with respect to the comparator method.

Leatham Bryan、Brown Bradley A.、Jacky Lucien、Gole Jeffery、Cabrera Kerri

ChromaCode Inc 2330 Faraday AveChromaCode Inc 2330 Faraday AveChromaCode Inc 2330 Faraday AveChromaCode Inc 2330 Faraday AveChromaCode Inc 2330 Faraday Ave

10.1101/2023.05.04.539400

医学研究方法肿瘤学分子生物学

Leatham Bryan,Brown Bradley A.,Jacky Lucien,Gole Jeffery,Cabrera Kerri.Analytical performance and concordance with next-generation sequencing of a rapid multiplexed dPCR panel for the detection of actionable DNA and RNA biomarkers in non-small cell lung cancer[EB/OL].(2025-03-28)[2025-05-11].https://www.biorxiv.org/content/10.1101/2023.05.04.539400.点此复制

评论