|国家预印本平台
| 注册
首页|Multivariate analysis of Compton-imaging detector response for neutron capture cross-section measurements

Multivariate analysis of Compton-imaging detector response for neutron capture cross-section measurements

luo, Mr. zhongxian Ren, Dr. Jie Wang, Dr. jincheng Ruan, Dr. Xichao Xue, Ms. Jieming Yang, Miss Haolan Bao, Dr. Jie Jiang, Dr. Wei Fan, Dr. Ruirui Huang, Dr. Hanxiong Luan, Dr. Guangyuan Zhang, Dr. Qiwei

✕

Multivariate analysis of Compton-imaging detector response for neutron capture cross-section measurements

Multivariate analysis of Compton-imaging detector response for neutron capture cross-section measurements

luo, Mr. zhongxian Ren, Dr. Jie 1Wang, Dr. jincheng 1Ruan, Dr. Xichao Xue, Ms. Jieming Yang, Miss Haolan 1Bao, Dr. Jie Jiang, Dr. Wei 2Fan, Dr. Ruirui 2Huang, Dr. Hanxiong Luan, Dr. Guangyuan 1Zhang, Dr. Qiwei

作者信息

  • 1. China Institute of Atomic Energy
  • 2. Chinese Academy of Sciences
  • 折叠

摘要

The imaging total-energy detector (i-TED) uses Compton imaging to suppress background in radiative neutron capture measurements, but stringent geometric selection often entails substantial losses in event statistics. This work investigates a TabM-based multivariate event-selection method using measurements at the back-streaming white neutron beamline (Back-n) of the China Spallation Neutron Source (CSNS). Capture-cascade, particle-transport and detector-response simulations are combined with $^{197}$Au sample measurements to evaluate background suppression and event retention. Experimental results show that TabM retains more coincidences than geometric selection at the same effect-to-background ratio. At equal selected counts, it achieves a higher ratio. Pulse-height weighting and selection-specific response calibration are combined with the corresponding experimental corrections to reconstruct the $^{197}$Au(n,$\gamma$) cross section. Both reconstructions retain the main Au resonance structures, and uncertainty propagation shows improved precision for TabM with response calibration and selection thresholds held fixed. In a separate weak-signal $^{209}$Bi simulation, multivariate selection retains more true capture events at equal selected counts, making resonance structures that are weak under geometric selection more distinct. The method improves the statistical efficiency of i-TED capture measurements and provides a basis for measurements of weak capture signals and mass-limited samples.

Abstract

The imaging total-energy detector (i-TED) uses Compton imaging to suppress background in radiative neutron capture measurements, but stringent geometric selection often entails substantial losses in event statistics. This work investigates a TabM-based multivariate event-selection method using measurements at the back-streaming white neutron beamline (Back-n) of the China Spallation Neutron Source (CSNS). Capture-cascade, particle-transport and detector-response simulations are combined with $^{197}$Au sample measurements to evaluate background suppression and event retention. Experimental results show that TabM retains more coincidences than geometric selection at the same effect-to-background ratio. At equal selected counts, it achieves a higher ratio. Pulse-height weighting and selection-specific response calibration are combined with the corresponding experimental corrections to reconstruct the $^{197}$Au(n,$\gamma$) cross section. Both reconstructions retain the main Au resonance structures, and uncertainty propagation shows improved precision for TabM with response calibration and selection thresholds held fixed. In a separate weak-signal $^{209}$Bi simulation, multivariate selection retains more true capture events at equal selected counts, making resonance structures that are weak under geometric selection more distinct. The method improves the statistical efficiency of i-TED capture measurements and provides a basis for measurements of weak capture signals and mass-limited samples.

关键词

GEANT4/Neutron capture cross-section/Machine learning/Cross section/Compton imaging/Measurement precision

引用本文复制引用

luo, Mr. zhongxian,Ren, Dr. Jie,Wang, Dr. jincheng,Ruan, Dr. Xichao,Xue, Ms. Jieming,Yang, Miss Haolan,Bao, Dr. Jie,Jiang, Dr. Wei,Fan, Dr. Ruirui,Huang, Dr. Hanxiong,Luan, Dr. Guangyuan,Zhang, Dr. Qiwei.Multivariate analysis of Compton-imaging detector response for neutron capture cross-section measurements[EB/OL].(2026-10-19)[2026-10-22].https://chinaxiv.org/abs/202610.00120.

学科分类

粒子探测技术、辐射探测技术、核仪器仪表
首发时间: 2026-10-19
下载量:0
|
点击量:9
段落导航相关论文