|国家预印本平台
| 注册
首页|A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction Encoding

A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction Encoding

Dillon J. Bass Bradley R. Johnson

✕
Arxiv_logoArxiv

A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction Encoding

Dillon J. Bass Bradley R. Johnson

作者信息

Abstract

Absolute polarization angle calibration of cosmic microwave background (CMB) telescopes at the $\lesssim 0.1^\circ$ level is needed to prevent instrumental mixing of $E$ modes into $B$ modes from biasing constraints on primordial gravitational waves and cosmic birefringence. Artificial polarized sky sources like drones, balloons, or satellites can provide calibration references, but transferring their emitted polarization angle from the payload frame to the celestial frame remains a challenge. We propose a calibrator architecture, applicable to any such source, in which a single dual-use grid-optic sets the polarization axis of the emitted millimeter-wave signal and also diffracts starlight into a co-aligned star camera. The resulting diffraction spectra record the grid's orientation relative to the stars, so that it can be measured directly on the sky without fine alignment between the camera and grid-optic. We describe the geometry and physics of this concept and show that it significantly simplifies obtaining the calibration angle the observatory needs, because precise payload attitude is no longer needed and the received polarization is insensitive to small line-of-sight errors. In simulations of 1000 real star fields that include camera-grid misalignment, lens distortion, lateral chromatic aberration, atmospheric refraction, and stellar colors, a single exposure recovers the polarizing grid-optic's orientation in the celestial frame with an uncertainty of $\simeq 0.002^\circ$, fifty times below the $0.1^\circ$ goal. We also discuss the hardware tolerances a physical calibrator must meet, which future work will test. Our results establish the feasibility of this approach and motivate development of a dual-use grid-optic.

引用本文复制引用

Dillon J. Bass,Bradley R. Johnson.A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction Encoding[EB/OL].(2026-11-18)[2026-11-23].https://arxiv.org/abs/2611.21794.

学科分类

天文学
首发时间: 2026-11-18
下载量:0
|
点击量:53
段落导航相关论文