|国家预印本平台
| 注册
首页|A low insertion loss L-band feed front-end for the FAST Core Array

A low insertion loss L-band feed front-end for the FAST Core Array

Jinglong Yu Hengqian Gan Yang Cao Xiaoming Chai Bin Liu Rurong Chen

✕

A low insertion loss L-band feed front-end for the FAST Core Array

A low insertion loss L-band feed front-end for the FAST Core Array

Jinglong Yu 1Hengqian Gan 2Yang Cao 2Xiaoming Chai 2Bin Liu 2Rurong Chen2

作者信息

  • 1. Guizhou Radio Astronomical Observatory, Guiyang 550025, China;National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China;University of Chinese Academy of Sciences, Beijing 100049, China
  • 2. Guizhou Radio Astronomical Observatory, Guiyang 550025, China;National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
  • 折叠

摘要

We designed a low insertion loss L-band feed front-end system to operate over a 1.15–1.75 GHz frequency range for the Five-hundred-meter Aperture Spherical radio Telescope (FAST) Core Array. The L-band feed front-end system comprises quadruple-ridge ortho-mode transducers and a choke horn. The coaxial output of the transducers extracts two mutually orthogonal polarization signals by coupling the input of a circular waveguide. Two non-cryogenic low temperature low-noise amplifiers with average noise of only 10 K at room temperature connected to coaxial outputs respectively. Because it operates at room temperature, the new developed ortho-mode transducer requires lower insertion loss than in designs intended to operate in extremely cold environments. This paper focuses on the 1.15–1.75 GHz L-Band ortho-mode transducer and choke horn design, with a measured L-band return loss of more than −20 dB, and an insertion loss of more than 0.09 dB. Considering the large quantity of front-end systems required for array applications, our design of ortho-mode transducers balances performance, adjustability, and ease of manufacture, and our choke horn design has high aperture efficiency across the L-band.

Abstract

We designed a low insertion loss L-band feed front-end system to operate over a 1.151.75 GHz frequency range for the Five-hundred-meter Aperture Spherical radio Telescope (FAST) Core Array. The L-band feed front-end system comprises quadruple-ridge ortho-mode transducers and a choke horn. The coaxial output of the transducers extracts two mutually orthogonal polarization signals by coupling the input of a circular waveguide. Two non-cryogenic low temperature low-noise amplifiers with average noise of only 10 K at room temperature connected to coaxial outputs respectively. Because it operates at room temperature, the new developed ortho-mode transducer requires lower insertion loss than in designs intended to operate in extremely cold environments. This paper focuses on the 1.151.75 GHz L-Band ortho-mode transducer and choke horn design, with a measured L-band return loss of more than 20 dB, and an insertion loss of more than 0.09 dB. Considering the large quantity of front-end systems required for array applications, our design of ortho-mode transducers balances performance, adjustability, and ease of manufacture, and our choke horn design has high aperture efficiency across the L-band.

关键词

Ortho-mode transducers/Feed/Reflector antenna/Quad-ridged/Choke horn

Key words

Ortho-mode transducers/Feed/Reflector antenna/Quad-ridged/Choke horn

引用本文复制引用

Jinglong Yu,Hengqian Gan,Yang Cao,Xiaoming Chai,Bin Liu,Rurong Chen.A low insertion loss L-band feed front-end for the FAST Core Array[EB/OL].(2026-11-19)[2026-11-23].https://chinaxiv.org/abs/202611.00192.

学科分类

天文学
首发时间: 2026-11-19
下载量:0
|
点击量:98
段落导航相关论文