|国家预印本平台
| 注册
首页|Multiscalenumericalpredictionoffrettingwearinducedbyflow-inducedvibrationinan LBE-cooledwire-wrappedfuelrodbundle

Multiscalenumericalpredictionoffrettingwearinducedbyflow-inducedvibrationinan LBE-cooledwire-wrappedfuelrodbundle

Wang, Sipeng Hui, Mr. Jingbo Qi, Mr. Ce Hu, Mr. Liming Liu, Mr. Yi zhuang, Dr. kun

✕

Multiscalenumericalpredictionoffrettingwearinducedbyflow-inducedvibrationinan LBE-cooledwire-wrappedfuelrodbundle

Multiscalenumericalpredictionoffrettingwearinducedbyflow-inducedvibrationinan LBE-cooledwire-wrappedfuelrodbundle

Wang, Sipeng 1Hui, Mr. Jingbo Qi, Mr. Ce Hu, Mr. Liming Liu, Mr. Yi zhuang, Dr. kun

作者信息

  • 1. Nanjing University of Aeronautics and Astronautics
  • 折叠

摘要

Fretting wear driven by flow-induced vibration threatens the integrity of wire-wrapped fuel assemblies in liquid-metal-cooled reactors, but quantitative prediction remains difficult because turbulent excitation, nonlinear contact, and local wear morphology evolve across different spatial and temporal scales. This study develops a cross-scale numerical framework for a CIADS 7-rod LBE-cooled wire-wrapped bundle by coupling LES-based fluid-force extraction, synthetic long-duration stochastic excitation, nonlinear structural contact analysis, Archard wear evaluation, and local moving-mesh wear simulation. Large eddy simulation is adopted to obtain short-term excitations, and an artificial synthesis method is applied to generate long-duration excitation forces as loads for finite element calculations. The solved contact information is utilized to compute wear power and time-averaged wear rates. The central rod shows little mean transverse-force bias, and its contact response is mainly governed by turbulent fluctuations, with the highest wear located along the Rod 4–Rod 7 direction. In contrast, peripheral Rod 2 experiences sustained rod-to-duct contact owing to a positive X-direction mean force, giving a maximum wear rate of 4.17×10⁻⁴ μm/year, higher than the central rod value of 2.45×10⁻⁴ μm/year. Both values remain very low under the conservative wear coefficient adopted in this study. The local moving-mesh simulation further reveals a running-in stage dominated by rapid wear-area expansion, followed by stable wear-depth accumulation within the established scar. The local model uses numerical acceleration to clarify morphology evolution and is not intended to directly predict absolute in-service wear depth. These results provide a cross-scale numerical basis for assessing FIV-induced fretting wear in LBE-cooled wire-wrapped fuel assemblies.

Abstract

Fretting wear driven by flow-induced vibration threatens the integrity of wire-wrapped fuel assemblies in liquid-metal-cooled reactors, but quantitative prediction remains difficult because turbulent excitation, nonlinear contact, and local wear morphology evolve across different spatial and temporal scales. This study develops a cross-scale numerical framework for a CIADS 7-rod LBE-cooled wire-wrapped bundle by coupling LES-based fluid-force extraction, synthetic long-duration stochastic excitation, nonlinear structural contact analysis, Archard wear evaluation, and local moving-mesh wear simulation. Large eddy simulation is adopted to obtain short-term excitations, and an artificial synthesis method is applied to generate long-duration excitation forces as loads for finite element calculations. The solved contact information is utilized to compute wear power and time-averaged wear rates. The central rod shows little mean transverse-force bias, and its contact response is mainly governed by turbulent fluctuations, with the highest wear located along the Rod 4Rod 7 direction. In contrast, peripheral Rod 2 experiences sustained rod-to-duct contact owing to a positive X-direction mean force, giving a maximum wear rate of 4.1710 m/year, higher than the central rod value of 2.4510 m/year. Both values remain very low under the conservative wear coefficient adopted in this study. The local moving-mesh simulation further reveals a running-in stage dominated by rapid wear-area expansion, followed by stable wear-depth accumulation within the established scar. The local model uses numerical acceleration to clarify morphology evolution and is not intended to directly predict absolute in-service wear depth. These results provide a cross-scale numerical basis for assessing FIV-induced fretting wear in LBE-cooled wire-wrapped fuel assemblies.

关键词

Lead-bismuth eutectic (LBE)/Flow-induced vibration/Fretting wear/Wire wrap/Numerical simulation

引用本文复制引用

Wang, Sipeng,Hui, Mr. Jingbo,Qi, Mr. Ce,Hu, Mr. Liming,Liu, Mr. Yi,zhuang, Dr. kun.Multiscalenumericalpredictionoffrettingwearinducedbyflow-inducedvibrationinan LBE-cooledwire-wrappedfuelrodbundle[EB/OL].(2026-11-22)[2026-11-25].https://chinaxiv.org/abs/202611.00212.

学科分类

核反应堆工程
首发时间: 2026-11-22
下载量:0
|
点击量:45