|国家预印本平台
首页|曝气量对生物膜法短程硝化反硝化工艺的影响研究

曝气量对生物膜法短程硝化反硝化工艺的影响研究

Effects of Aeration in Biofilm Nitrogen Removal Process Based on Short-cut Nitrification and Denitrification

中文摘要英文摘要

本文研究了低碳氮比条件下生物膜法短程硝化反硝化工艺中曝气量对DO、NH4+、NO2-、NO3-的浓度以及氨氮和总氮去除率的影响研究。结果表明,在曝气量为20-50mL/min时,随着曝气量的增大,DO逐渐增大,出水NH4+浓度降低,出水NO2-浓度升高,并在25-40mg/L之间变化,出水NO3-浓度较稳定,维持在15mg/L左右;随着曝气量增加,NO2-累计率呈先增加后稳定趋势,总氮TN和氨氮的去除率呈上升趋势;DO对各因素的影响与曝气量一致。

In this paper, starting and process control of autotrophic denitrification biofilm process on low-carbon conditions was studied. The large number of databases showed when the ammonia concentration of influent was 70 - 190mg / L, the NO2-/NO3- maintained the level of 79 ± 2%, the system was stable as the concentration of ammonia ranged from 70 mg / L to 190 mg / L, but the removal rate of ammonia and total nitrogen decreases; Optimal HRT was 8h; Best pH was8.0; DO was a key factor in nitrite accumulation, the system runs well when DO was in the 0.8-1.0mg / L; When the organic content was not higher than 100mg / L, the impact on the system was smallest; microorganisms in the system grew well on 28 ℃.

王健

环境科学技术现状环境生物学

生物膜法短程硝化反硝化曝气溶解氧

low C/N ratioBiofilmnitrosationautotrous nitrogen removal

王健.曝气量对生物膜法短程硝化反硝化工艺的影响研究[EB/OL].(2011-01-14)[2025-08-02].http://www.paper.edu.cn/releasepaper/content/201101-718.点此复制

评论