|国家预印本平台
首页|ZVS移相全桥DC/DC变换器抗电网电压扰动能力分析

ZVS移相全桥DC/DC变换器抗电网电压扰动能力分析

nalysis on Anti-grid Voltage Disturbance Capacity of Phase-Shifted Full-Bridge ZVS DC/DC Converter

中文摘要英文摘要

本文以蓄电池充电系统为研究背景,在建立了ZVS移相全桥DC/DC变换器小信号等效电路模型的基础上,推导出了其传递函数,并据此设计了电压模式单闭环控制器。针对系统抗市电电网电压扰动的能力,给出了音频信号衰减率的传递函数,对开环控制及单闭环电压模式控制下系统的抗电网扰动能力进行理论分析和仿真验证。

Based on the background of battery charging system, in this paper, the small-signal equivalent circuit model of phase-shifted full-bridge ZVS DC / DC converter is established, then its transfer function is derived, and a single closed-loop voltage-mode controller is designed. In order to analyze anti grid voltage disturbance capacity, transfer function of audio susceptibility is presented, and the anti-grid voltage disturbance capacity in open-loop system and single closed-loop system is analyzed in theory and is verified by simulation respectively.

赵晨曦、赵琛

变压器、变流器、电抗器

移相全桥DC/DC变换器小信号模型音频信号衰减率电压模式控制

phase-shifted full-bridge DC / DC convertersmall-signal modelaudio susceptibilityvoltage mode control

赵晨曦,赵琛.ZVS移相全桥DC/DC变换器抗电网电压扰动能力分析[EB/OL].(2010-07-15)[2025-08-21].http://www.paper.edu.cn/releasepaper/content/201007-302.点此复制