首页|Establishment and study of a polarized X-ray radiation facility

Establishment and study of a polarized X-ray radiation facility

Establishment and study of a polarized X-ray radiation facility

中文摘要英文摘要

With the advancement in X-ray astronomical detection technology, various celestial polarization detection projects have been initiated. To meet the calibration requirements of polarimeters on the ground, a polarized X-ray radiation facility was designed for this study. The design was based on the principle that X-rays incident at 45$^\circ$ on a crystal produce polarized X-rays, and a second crystal was used to measure the polarization of the X-rays produced by the facility after rotation. The effects of different diaphragm sizes on the degree of polarization were compared, and the facility produced X-rays with polarization degrees of up to 99.55$\pm$0.96\% using LiF200 and LiF220 crystals. This result revealed that the polarization of incident X-rays is one of the factors affecting the diffraction efficiency of crystals. The replacement of different crystals can satisfy the calibration requirements of polarized X-ray detectors with more energy points in the energy range (4–10) keV. In the future, the facility should be placed in a vacuum environment to meet the calibration requirements at lower energies.

With the advancement in X-ray astronomical detection technology, various celestial polarization detection projects have been initiated. To meet the calibration requirements of polarimeters on the ground, a polarized X-ray radiation facility was designed for this study. The design was based on the principle that X-rays incident at 45 on a crystal produce polarized X-rays, and a second crystal was used to measure the polarization of the X-rays produced by the facility after rotation. The effects of different diaphragm sizes on the degree of polarization were compared, and the facility produced X-rays with polarization degrees of up to 99.55±0.96% using LiF200 and LiF220 crystals. This result revealed that the polarization of incident X-rays is one of the factors affecting the diffraction efficiency of crystals. The replacement of different crystals can satisfy the calibration requirements of polarized X-ray detectors with more energy points in the energy range (4–10) keV. In the future, the facility should be placed in a vacuum environment to meet the calibration requirements at lower energies.

Fan, Lipeng、Guo, Kaiyue、Yu, Tao、Huang, Shikui、Zhou, Xing、Wu, Jinjie、Guo, Siming、Huang, Yongbo、Shu, Ziyao、Qie, Xiaoyu

10.12074/202307.00202V1

物理学晶体学粒子探测技术、辐射探测技术、核仪器仪表

: Polarized X-raysPolarimetryCalibrationBragg diffraction

: Polarized X-raysPolarimetryCalibrationBragg diffraction

Fan, Lipeng,Guo, Kaiyue,Yu, Tao,Huang, Shikui,Zhou, Xing,Wu, Jinjie,Guo, Siming,Huang, Yongbo,Shu, Ziyao,Qie, Xiaoyu.Establishment and study of a polarized X-ray radiation facility[EB/OL].(2023-07-18)[2025-08-02].https://chinaxiv.org/abs/202307.00202.点此复制

评论