omputation and parameterization of normalized glandular dose using Geant4
omputation and parameterization of normalized glandular dose using Geant4
he average absorbed dose in glandular tissue is the most appropriate parameter for the assessment of the radiation-induced risk during breast imaging. The aims of this work concern: (1) the investigation of the variation effect of any related update to photon cross-section data-bases on the computation of the normalized glandular dose (DgN) for mammography quality control tests and (2) the proposition of a parameterization method leading to provide DgN values function of the breast thickness (T) and the particle energy (E) instead of E alone, as normally known. We analyzed the change effect of the photon cross-section data-bases on the computation of DgN. Those coefficients, generated using the Geant4 Monte Carlo toolkit, were studied over a range of compressed breast thickness of 2–8 cm for monoenergetic (1–120 keV by 1 keV intervals) and polyenergetic (23–35 kVp by 2 kVp intervals) X-ray beams. Moreover, breast tissue composition ranging from about 0% glandular (about 100% adipose) to 100% glandular (0% adipose) was also covered. The successful parameterization of DgN look-up table function of the breast thickness and energy, will compact its analytical form without loss of accuracy. All parameterization fits resulted in r2 values of 0.999 or better.
he average absorbed dose in glandular tissue is the most appropriate parameter for the assessment of the radiation-induced risk during breast imaging. The aims of this work concern: (1) the investigation of the variation effect of any related update to photon cross-section data-bases on the computation of the normalized glandular dose (DgN) for mammography quality control tests and (2) the proposition of a parameterization method leading to provide DgN values function of the breast thickness (T) and the particle energy (E) instead of E alone, as normally known. We analyzed the change effect of the photon cross-section data-bases on the computation of DgN. Those coefficients, generated using the Geant4 Monte Carlo toolkit, were studied over a range of compressed breast thickness of 2–8 cm for monoenergetic (1–120 keV by 1 keV intervals) and polyenergetic (23–35 kVp by 2 kVp intervals) X-ray beams. Moreover, breast tissue composition ranging from about 0% glandular (about 100% adipose) to 100% glandular (0% adipose) was also covered. The successful parameterization of DgN look-up table function of the breast thickness and energy, will compact its analytical form without loss of accuracy. All parameterization fits resulted in r2 values of 0.999 or better.
Kadri Omrane、Shamma Khaled、Ali Alnafea Mohammed
dx.doi.org/10.13538/j.1001-8042/nst.26.030303
基础医学原子能技术基础理论放射性同位素生产辐射防护粒子探测技术、辐射探测技术、核仪器仪表
Monte Carlo simulationGeant4Normalized glandular doseParameterization
Monte Carlo simulationGeant4Normalized glandular doseParameterization
Kadri Omrane,Shamma Khaled,Ali Alnafea Mohammed.omputation and parameterization of normalized glandular dose using Geant4[EB/OL].(2023-06-18)[2025-08-02].https://chinaxiv.org/abs/202306.00279.点此复制