基于topsis模型的火灾报警系统研究

Research on fire alarm system based on topsis model

中文摘要英文摘要

火灾防治主要分为火灾预防及灾后治理两方面,其中使用火灾报警系统是火灾预防的有效方式。为预防火灾事故的发生,提高火灾报警系统的效率,以某城市六月份前半月的火灾数据为例,通过收集17个火灾探测器的报警数据统计出真实火灾数,通过熵权法计算准确率、火灾探测器使用占比、误报警率、故障率等四个指标权重,以此建立基于 Topsis 的火灾探测器可靠性评价模型,得出各种探测器的综合得分系数排名。为研究火灾防治火灾探测器类型的选取提供了参考。

Fire prevention and control is mainly divided into two aspects: fire prevention and post-disaster management, among which the use of fire alarm system is an effective way of fire prevention. To prevent fire accidents, improve the efficiency of fire alarm system, to a certain city in June and a half months before the fire data, for example, by collecting 17 fire detector alarm data statistics of a real fire, through the entropy weight method to calculate accuracy, fire detector using proportion, four indexes such as false alarm rate and fault rate of the weight, The reliability evaluation model of fire detectors based on Topsis is established, and the comprehensive score coefficient ranking of various detectors is obtained. It provides a reference for the selection of fire detector types for fire prevention and control.

黎远康、张万起、杨涓、刘宇、翟泓武

灾害、灾害防治安全科学自动化技术、自动化技术设备

火灾防治熵权法火灾报警系统可靠性评价

fire prevention and controlkeytopsisfire alarm systemevaluation of reliability

黎远康,张万起,杨涓,刘宇,翟泓武.基于topsis模型的火灾报警系统研究[EB/OL].(2022-11-17)[2025-08-16].http://www.paper.edu.cn/releasepaper/content/202211-36.点此复制