esign and test for the CEPC muon subdetector based on extruded scintillator and SiPM
esign and test for the CEPC muon subdetector based on extruded scintillator and SiPM
br />A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows excellent performance in the `KL and μ detector (KLM)' of the Belle II experiment. We describe the R&D for a similar detection technology with a new scintillator and SiPM, which can be implemented for a muon detector for the proposed CEPC experiment and the upgrade of KLM in Belle II. The R&D contains the study of the performance of a new scintillator with a length of 150 cm, the NDL SiPM with a sensitive surface of 3 mm × 3 mm or the Hamamatsu MPPC with a sensitive surface of 1.3 mm × 1.3 mm, the construction of a detector strip, and the methods to achieve excellent light collection. The cosmic ray tests show good photon collections by NDL SiPM or MPPC, efficiencies well above 90% with a threshold of 8 p.e., and time resolutions of better than 1.7 ns for the hits at the far end of a scintillator strip. The performance shows a good option for an excellent muon detector for CEPC and the possible upgrade of Belle II KLM.
combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `KL and detector (KLM)' of the Belle II experiment. In this study, we present the R&D efforts for a similar detection technology utilizing a new scintillator and SiPM. This technology can be applied to a muon detector for the proposed CEPC experiment. The R&D encompasses the investigation of the performance of a new 150 cm-long scintillator, the NDL SiPM with a sensitive surface of 3 mm 3 mm, or the Hamamatsu MPPC with a sensitive surface of 1.3 mm 1.3 mm. Additionally, it includes the construction of a detector strip and the methods employed to achieve excellent light collection. Cosmic ray tests reveal efficient photon collections by NDL SiPM or MPPC, with efficiencies well above 90% using a threshold of 8 p.e.. The time resolutions for hits at the far end of a scintillator strip are better than 1.7 ns. The observed performance indicates a promising option for an outstanding muon detector for CEPC.
粒子探测技术、辐射探测技术、核仪器仪表
Muon detectorscintillatorsilicon photomultiplierCEPC
Muon detectorscintillatorsilicon photomultiplierCEPC
.esign and test for the CEPC muon subdetector based on extruded scintillator and SiPM[EB/OL].(2024-02-25)[2025-08-16].https://chinaxiv.org/abs/202312.00080.点此复制
评论