一种无坐标变换谐波及无功电流检测方法
NOVEL HARMONIC AND REACTIVE CURRENT DETECTION METHOD WITHOUT CORDINATE TRANSFORM
本文提出了一种能在电网电压畸变和不对称条件下方便提取电网中谐波和无功电流的检测算法。基于瞬时无功功率理论,通过对三相电压和电流算法的改进,实现谐波和无功电流的提取。补偿电流采用滞环电流控制,获得了较好的补偿特性和控制精度。通过对三相有源电力滤波器的仿真,实验结果表明所提算法具有抑制电压畸变带来的影响和算法简单的优点。
he paper presents a detection method, which can expediently extract harmonic and reactive currents under asymmetric or distorted supply voltage conditions. The proposed method extracts harmonic and reactive currents through three-phase voltage and current algorithmic amendatory based on instantaneous reactive power theory. Hysteresis current control is adopted to obtain compensation currents, which has good compensation performance and control precision. Simulations of three-phase active power filter show that the proposed detection has merits of simple arithmetic and it can restrain the infection resulting from distorted supply voltage.
王照敏、林善明
电气测量技术、电气测量仪器电工基础理论
有源电力滤波器瞬时无功功率理论谐波电流检测滞环控制
active power filterinstantaneous reactive power theoryharmonic current detectionhysteresis current control
王照敏,林善明.一种无坐标变换谐波及无功电流检测方法[EB/OL].(2008-09-03)[2025-08-16].http://www.paper.edu.cn/releasepaper/content/200809-87.点此复制