|国家预印本平台
首页|采用现场检测数据与历史数据进行比对的线路故障检测系统

采用现场检测数据与历史数据进行比对的线路故障检测系统

Line Fault Detection System by Comparing on-site Testing Data with Historical Data

中文摘要英文摘要

本论文针对当前线路故障检测设备提出改进措施。本设备是采用现场观测的具体数据及工作人员的具体要求设计的。主要体现在硬件方面:电源采用了太阳能板,能保证设备在户外长久的运行;报警器选用时钟芯片产生三种不同的报警信号,它可非常直观的反映是哪一相发生问题。软件方面增加一个建立现场数据库的功能,能很好的记录现场数据,为以后设备的进步改善和研究提供最真实最有价值的数据信息。

bstract:This paper put forward some improvement measures on the current line fault detection equipment. This equipment is used on-site observation of the specific data and the staff of the specific design requirements. On hardware, using solar power panels for power supply, which could ensure the equipment long running outdoors; clock chips with three different alarm signals are used in alarm, which could be very intuitive to reflect what happened with the problem. On software, increasing the capability to establish an on-site database, which could take a very good record of on-site data, and this would provide most valuable real data for future equipment advances.

卫印红、关海鹏、冯介一

输配电工程电气测量技术、电气测量仪器

单片机嵌入式数据库线路故障检测

Key Single-chipEmbeddedDatabaseLine fault detection

卫印红,关海鹏,冯介一.采用现场检测数据与历史数据进行比对的线路故障检测系统[EB/OL].(2009-02-26)[2025-08-19].http://www.paper.edu.cn/releasepaper/content/200902-1427.点此复制